A total of 109 publications reporting 123 studies (14 publications each reported two substudies) were included in the review: 65 case reports, 28 seropositivity studies and 30 diagnostic accuracy studies.
Eight studies were excluded from the quality assessment. Cause of fever, seroepidemiology studies and diagnostic accuracy studies all scored a median of 3 (interquartile range, IQR: 2 to 4); case-studies were of poorer quality with a median score of 2 (IQR: 1 to 3). There was no overall improvement in quality over time.
Most studies used a defined cut-off titre rather than an increase in the titre in paired samples. The choice of positivity cut-off varied by country (p=0.012) and purpose of the IFA test. Only 25 of the 69 studies that stated a criterion for seropositive results justified this choice by citing a previous study. The most frequently cited study suggested a cut-off titre of 1:400 and at least a 4-fold increase in the titre in paired serum samples..
Prevalence data could only be extracted from 32 studies. Prevalence data were not reported in full but, where reported, ranged from 0.4 to 90.5%. There was a correlation between prevalence rate and positivity cut-off titre (r2=0.22, p=0.007). This correlation was higher in the seroprevalence studies (r2=0.33, p=0.008). The association was not significant for the fever studies (p=0.15) or diagnostic accuracy studies (p=0.14).